The Physio-Control LIFEPAK CR Plus/EXPRESS CHARGE-PAK
Includes:
- 2 Electrodes/Pads
- 1 CHARGE-PAK charging unit
- Replacement instructions
- 1 Battery discharger (Used to safely drain a used CHARGE-PAK prior to disposal or recycling)
This CHARGE-PAK is for the LIFEPAK CR Plus or the LIFEPAK EXPRESS AED.
The Physio-Control CR Plus LIFEPAK AED and LIFEPAK EXPRESS AED function slightly differently from
other AEDs. Instead of a battery, these AEDs use the Physio-Control CHARGE-PAK
battery system, which charges an internal, permanent battery inside the AED
device. After an AED use or about two years (whichever comes first), the
battery charger and electrode pads both need to be replaced.
The cost to replace the CHARGE-PAK and
electrode pads for the CR Plus or EXPRESS is about as much or a little more
than replacing just electrode pads on many comparable AEDs. On other AEDs, you
also have to replace the battery periodically, and that’s typically a higher
cost. When the battery charger and electrode pads are on the same replacement
cycle, you know your LIFEPAK CR Plus or EXPRESS is ready for use.
When you replace the battery charger, it
begins to charge or top off the defibrillator’s internal battery. Depending on
temperature, the full process can take anywhere from a few days up to two
weeks.
- If the AED was used recently,
it may take up to three days to top off the battery at normal room
temperature of 68°F or 20°C
- During this time, the caution
symbol (!) will be visible on the Readiness Display. When the caution
symbol turns off, the device will be able to shock at least six times or
provide 42 minutes of “on” time
- When the device switches to
“OK” on the Readiness Display, the CHARGE-PAK will still continue to
trickle charge the battery until it reaches full capacity. At normal room
temperature, this may take up to two weeks. It may take longer at lower
temperatures. Please note the battery may not charge at temperatures lower
than 32°F or 0°C.
A CHARGE-PAK battery charger becomes
internally linked to the first AED into which it is inserted. A CHARGE-PAK
cannot be removed from one AED and inserted into another; it won’t charge the
second AED. If this happens, the battery charger must be discarded and
replaced.
When using the CHARGE-PAK discharger, allow
nine days for the discharge process to complete before recycling or disposing
of the used CHARGE-PAK.
Important Note:
The LIFEPAK CR Plus/LIFEPAK EXPRESS
defibrillation electrode pads and battery charger are sold only as a kit and
are not available as separately orderable items. Both the battery/charger and
defibrillation electrode pads are replaced simultaneously either upon use or
expiration. We ensure the expiration dates of both components in this kit are
exactly the same.
Alternate Part
Number(s): 3200727-002, 3201616-001, 3201616-003, 3202176-003, 3202176-005,
3202176, 3202176-006, 3202176-007, 3202176-008, 3200727-005, 11403-000002,
11403-000001, 3200731-009, 3200731-002, 3200731-003
To be indemnified under the Good Samaritan Law, follow manufacturers guidelines. Use AEDSafetrack Program Management to document that your AED is compliant with local and state laws.
Physio-Control LIFEPAK CR Plus/EXPRESS CHARGE-PAK with 2 Sets of Adult Electrodes
- Brand: Physio-Control AEDs and Accessories
- Product Code: CR Plus Chargepack 11403-000001
- Availability: 30
-
$391.00